How to do the maintenance on an Aqua-Protec system

Modified on Fri, 26 Aug 2022 at 03:58 PM

The system has the ability to verify itself each week to ensure you are protected.

However, some maintenance may be necessary on the system depending on the number of sewer backups you blocked each year.

The only part that cannot be verified by the system is the sensors. The sensors show less sensitivity when the system has blocked a lot of sewer backups and that debris has likely stuck to the sensors themselves.

The verification is mandatory at each 10 sewer backups or after 5 years service to ensure that the system will continue to quickly respond to sewer backup events. However, depending on the number of logged sewer backups and the local installation environment, we recommend doing a quick verification each year.

The normal evacuation process of water will not affect the sensors since the bladder form creates a bubble underneath the bladder to make sure the waster water doesn’t touch the sensors.

The maintenance should take around 1h maximum to remove the bladder from the clean-out, clean the sensors, verify the connections, put back the bladder inside the clean-out and perform a partial and full system test. The maintenance should be done by the installer of the system.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons

Feedback sent

We appreciate your effort and will try to fix the article